Bolt Torque Calculator
Get a tightening torque for metric bolts from size, strength grade and thread condition. The tool also shows the bolt preload in kN.
Questions
What formula is used?
Torque = K × diameter × preload. Preload = percent × proof strength × tensile stress area. K is the friction factor of the threads and under-head surface.
Why 75 percent of proof?
Many reusable joints are tightened to 75 percent of proof load. Permanent joints may use up to 90 percent. Use the value your drawing or standard asks for.
Does lubrication change the torque?
Yes. The same torque on an oiled bolt gives more clamp force than on a dry one, so use the matching K-factor. Cutting the torque for oiled bolts avoids over-tightening.
Is this for critical joints?
No. Engine, wheel, structural and pressure joints have their own torque specs. Always use the maker’s figure for those.